Interior PM Generator for Portable AC Generator Sets

Date

2014

Authors

Soong, W.
Kahourzade, S.
Liaw, C.-Z.
Lillington, P.

Editors

Advisors

Journal Title

Journal ISSN

Volume Title

Type:

Conference paper

Citation

IEEE, 2014, pp.2425-2433

Statement of Responsibility

Conference Name

Sixth Annual IEEE on Energy conversion Congress and Exposition (14 Sep 2014 - 18 Sep 2015 : Pittsburgh, Pennsylvania)

Abstract

For portable AC electric generator sets, it is desired to maintain a constant output voltage under load. With wound-field synchronous generators this is done using field current (excitation) control. This type of control is not possible with PM machines however theoretical analysis is used to show that acceptable output voltage regulation can be obtained by using an optimized interior PM machine. The analysis of an example 4 pole, 16 kW spoke-type machine is described and experimental results are provided demonstrating its low THD, high voltage regulation and high efficiency.