Interior PM Generator for Portable AC Generator Sets
Date
2014
Authors
Soong, W.
Kahourzade, S.
Liaw, C.-Z.
Lillington, P.
Editors
Advisors
Journal Title
Journal ISSN
Volume Title
Type:
Conference paper
Citation
IEEE, 2014, pp.2425-2433
Statement of Responsibility
Conference Name
Sixth Annual IEEE on Energy conversion Congress and Exposition (14 Sep 2014 - 18 Sep 2015 : Pittsburgh, Pennsylvania)
Abstract
For portable AC electric generator sets, it is desired to maintain a constant output voltage under load. With wound-field synchronous generators this is done using field current (excitation) control. This type of control is not possible with PM machines however theoretical analysis is used to show that acceptable output voltage regulation can be obtained by using an optimized interior PM machine. The analysis of an example 4 pole, 16 kW spoke-type machine is described and experimental results are provided demonstrating its low THD, high voltage regulation and high efficiency.
School/Discipline
Dissertation Note
Provenance
Description
Data source: Figures, https://ieeexplore.ieee.org/document/6953563/figures#figures
Access Status
Rights
Copyright 2014 IEEE