Comparison of three bioelectrical impedance methods with DXA in overweight and obese men
| dc.contributor.author | Brinkworth, G. | |
| dc.contributor.author | Buckley, J. | |
| dc.contributor.author | Noakes, M. | |
| dc.contributor.author | Clifton, P. | |
| dc.contributor.author | Pateyjohns, I. | |
| dc.date.issued | 2006 | |
| dc.description.abstract | <h4>Objective</h4>To compare bioelectrical impedance analysis (BIA) of body composition using three different methods against DXA in overweight and obese men.<h4>Research methods and procedures</h4>Forty-three healthy overweight or obese men (ages 25 to 60 years; BMI, 28 to 43 kg/m(2)) underwent BIA assessment of body composition using the ImpediMed SFB7 (version 6; ImpediMed, Ltd., Eight Mile Plains, Queensland, Australia) in multifrequency mode (Imp-MF) and DF50 single-frequency mode (Imp-SF) and the Tanita UltimateScale (Tanita Corp., Tokyo, Japan). Validity was assessed by comparison against DXA using linear regression and limits of agreement analysis.<h4>Results</h4>All three BIA methods showed good relative agreement with DXA [Imp-MF: fat mass (FM), r(2) = 0.81; fat-free mass (FFM), r(2) = 0.81; percentage body fat (BF%), r(2) = 0.69; Imp-SF: FM, r(2) = 0.65; FFM, r(2) = 0.76; BF%, r(2) = 0.40; Tanita: BF%, r(2) = 0.44; all p < 0.001]. Absolute agreement between DXA and Imp-MF was poor, as indicated by a large bias and wide limits of agreement (bias, +/-1.96 standard deviation; FM, -6.6 +/- 7.7 kg; FFM, 8.0 +/- 7.1 kg; BF%, -7.0 +/- 6.6%). Imp-SF and Tanita exhibited a smaller bias but wide limits of agreement (Imp-SF: FM, -1.1 +/- 8.5 kg; FFM, 2.5 +/- 7.9 kg; BF%, -1.7 +/- 7.3%; Tanita: BF%, 1.2 +/- 9.5%).<h4>Discussion</h4>Compared with DXA, Imp-MF produced large bias and wide limits of agreement, and its accuracy estimating body composition in overweight or obese men was poor. Imp-SF and Tanita demonstrated little bias and may be useful for group comparisons, but their utility for assessment of body composition in individuals is limited. | |
| dc.description.statementofresponsibility | Ian R. Pateyjohns, Grant D. Brinkworth, Jonathan D. Buckley, Manny Noakes and Peter M. Clifton | |
| dc.identifier.citation | Obesity, 2006; 14(11):2064-2070 | |
| dc.identifier.doi | 10.1038/oby.2006.241 | |
| dc.identifier.issn | 1930-7381 | |
| dc.identifier.issn | 1930-739X | |
| dc.identifier.orcid | Buckley, J. [0000-0003-0298-2186] | |
| dc.identifier.orcid | Clifton, P. [0000-0002-6411-626X] | |
| dc.identifier.uri | http://hdl.handle.net/2440/35733 | |
| dc.language.iso | en | |
| dc.publisher | North Amer Assoc Study Obesity | |
| dc.rights | Copyright status unknown | |
| dc.source.uri | https://doi.org/10.1038/oby.2006.241 | |
| dc.subject | bioelectrical impedance analysis | |
| dc.subject | body composition | |
| dc.subject | body fat | |
| dc.subject | multifrequency | |
| dc.subject | single-frequency | |
| dc.title | Comparison of three bioelectrical impedance methods with DXA in overweight and obese men | |
| dc.type | Journal article | |
| pubs.publication-status | Published |