Decision process for comparison of partial and complete XANES spectra

dc.contributor.authorZheng, J.
dc.contributor.authorEdraki, M.
dc.contributor.authorHuynh, T.
dc.contributor.authorGasparon, M.
dc.contributor.authorNg, J.
dc.contributor.authorHarris, H.
dc.contributor.authorNoller, B.
dc.contributor.conferenceInternational Conference on Synchrotron Radiation Instrumentation (10th : 2009 : Melbourne, Australia)
dc.contributor.editorGarrett, R.
dc.contributor.editorGentle, I.
dc.contributor.editorNugent, K.
dc.contributor.editorWilkins, S.
dc.date.issued2010
dc.descriptionAlso published as: AIP Conference Proceedings, 2010; 1234(1):621-624
dc.description.abstractIf the range of XANES spectra varies between sets of scans, it may be impossible to compare sets of spectra unless a restricted part of the spectra is used. The paper derives a decision process for comparison of partial and complete XANES spectra, taking lead as an example. Lead L3-edge XANES spectra were collected at the Australian National Beamline Facility (BL-20B) Photon Factory, Tsukuba, Japan over the energy range 13,000-13,150 eV (ring conditions: 2.5 GeV, 300-400 mA). The monochromator step size was reduced to 0.25 eV per step in the XANES region (13,000-13,100 eV and 13,040-13,100 eV) to collect high-resolution spectra. XANES data for samples and model compounds were collected at ambient temperature and pressure in fluorescence, using simultaneous collection of a Pb metal reference foil for energy calibration (first derivative peak of elemental Pb was 13,050 eV). XANES spectra were fitted using spectral deconvolution and least-squares linear combination fitting (LCF). Detailed XANES results with LCF approach over various energy ranges are illustrated and discussed and show the applicability of the decision-making procedure to compare sets of spectra. © 2010 American Institute of Physics.
dc.description.statementofresponsibilityJ. J. Zheng, M. Edraki, T. Huynh, M. Gasparon, J. Ng, H. H. Harris, and B. Noller
dc.identifier.citationSRI 2009 : the 10th International Conference on Synchrotron Radiation Instrumentation / R. Garrett, I. Gentle, K. Nugent, S. Wilkins (eds.): pp.621-624
dc.identifier.doi10.1063/1.3463283
dc.identifier.isbn9780735407824
dc.identifier.issn0094-243X
dc.identifier.issn1551-7616
dc.identifier.orcidHarris, H. [0000-0002-3472-8628]
dc.identifier.urihttp://hdl.handle.net/2440/64556
dc.language.isoen
dc.publisherAIP
dc.publisher.placeUSA
dc.relation.ispartofseriesAIP Conference Proceedings
dc.rights©2010 American Institute of Physics
dc.source.urihttps://doi.org/10.1063/1.3463283
dc.subjectX-ray absorption spectra
dc.subjectX-ray fluorescence
dc.subjectX-ray diffraction
dc.titleDecision process for comparison of partial and complete XANES spectra
dc.typeConference paper
pubs.publication-statusPublished

Files