Decision process for comparison of partial and complete XANES spectra
dc.contributor.author | Zheng, J. | |
dc.contributor.author | Edraki, M. | |
dc.contributor.author | Huynh, T. | |
dc.contributor.author | Gasparon, M. | |
dc.contributor.author | Ng, J. | |
dc.contributor.author | Harris, H. | |
dc.contributor.author | Noller, B. | |
dc.contributor.conference | International Conference on Synchrotron Radiation Instrumentation (10th : 2009 : Melbourne, Australia) | |
dc.contributor.editor | Garrett, R. | |
dc.contributor.editor | Gentle, I. | |
dc.contributor.editor | Nugent, K. | |
dc.contributor.editor | Wilkins, S. | |
dc.date.issued | 2010 | |
dc.description | Also published as: AIP Conference Proceedings, 2010; 1234(1):621-624 | |
dc.description.abstract | If the range of XANES spectra varies between sets of scans, it may be impossible to compare sets of spectra unless a restricted part of the spectra is used. The paper derives a decision process for comparison of partial and complete XANES spectra, taking lead as an example. Lead L3-edge XANES spectra were collected at the Australian National Beamline Facility (BL-20B) Photon Factory, Tsukuba, Japan over the energy range 13,000-13,150 eV (ring conditions: 2.5 GeV, 300-400 mA). The monochromator step size was reduced to 0.25 eV per step in the XANES region (13,000-13,100 eV and 13,040-13,100 eV) to collect high-resolution spectra. XANES data for samples and model compounds were collected at ambient temperature and pressure in fluorescence, using simultaneous collection of a Pb metal reference foil for energy calibration (first derivative peak of elemental Pb was 13,050 eV). XANES spectra were fitted using spectral deconvolution and least-squares linear combination fitting (LCF). Detailed XANES results with LCF approach over various energy ranges are illustrated and discussed and show the applicability of the decision-making procedure to compare sets of spectra. © 2010 American Institute of Physics. | |
dc.description.statementofresponsibility | J. J. Zheng, M. Edraki, T. Huynh, M. Gasparon, J. Ng, H. H. Harris, and B. Noller | |
dc.identifier.citation | SRI 2009 : the 10th International Conference on Synchrotron Radiation Instrumentation / R. Garrett, I. Gentle, K. Nugent, S. Wilkins (eds.): pp.621-624 | |
dc.identifier.doi | 10.1063/1.3463283 | |
dc.identifier.isbn | 9780735407824 | |
dc.identifier.issn | 0094-243X | |
dc.identifier.issn | 1551-7616 | |
dc.identifier.orcid | Harris, H. [0000-0002-3472-8628] | |
dc.identifier.uri | http://hdl.handle.net/2440/64556 | |
dc.language.iso | en | |
dc.publisher | AIP | |
dc.publisher.place | USA | |
dc.relation.ispartofseries | AIP Conference Proceedings | |
dc.rights | ©2010 American Institute of Physics | |
dc.source.uri | https://doi.org/10.1063/1.3463283 | |
dc.subject | X-ray absorption spectra | |
dc.subject | X-ray fluorescence | |
dc.subject | X-ray diffraction | |
dc.title | Decision process for comparison of partial and complete XANES spectra | |
dc.type | Conference paper | |
pubs.publication-status | Published |