Column separation experiments with large pressure pulses

dc.contributor.authorSimpson, A.
dc.contributor.authorWylie, E.
dc.contributor.conferencePressure Vessel and Piping Conference (1987 : San Diego, California, USA)
dc.date.issued1987
dc.description.abstractExperimental records of examples of distributed cavitation in a pipeline, and of concentrated cavitation at a specific location are presented. The slope of the piezometric level relative to the pipe slope at the time of vaporization controls the type of cavitation. Short duration high amplitude pressure pulses, ie. , times considerably less than 2 L/a seconds in a simple reservoir-pipe-valve system, are shown to occur in cases of localized cavitation, and to be much less apparent in cases in which distributed vaporous cavitation occurs prior to the collapse of the first cavity at the valve. With extensive distributed vaporization along the pipeline the particular short duration pulses of concern are not present.
dc.identifier.citationProceedings of ASME Pressure Vessel and Piping Conference, 1987 / Paper 87-PVP-18
dc.identifier.issn0402-1215
dc.identifier.orcidSimpson, A. [0000-0003-1633-0111]
dc.identifier.urihttp://hdl.handle.net/2440/80887
dc.language.isoen
dc.publisherASME
dc.rightsCopyright status unknown
dc.titleColumn separation experiments with large pressure pulses
dc.typeConference paper
pubs.publication-statusPublished