Abstract

A simple method for analyzing the steady-state performance of a self-excited induction generator with P-Q load model is described in this letter. First, the basic operating equations of the generator are derived from its equivalent circuit, and then solved using a numerical-based routine. The proposed method is then tested on a 1.5-kW induction generator and the simulation results obtained are compared with the corresponding experimental values.

School/Discipline

Dissertation Note

Provenance

Description

Access Status

Rights

Copyright 2009 IEEE Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works.