Air exchanges and indoor carbon dioxide concentration in Australian pig buildings: Effect of housing and management factors

dc.contributor.authorBanhazi, T.
dc.contributor.authorStott, P.
dc.contributor.authorRutley, D.
dc.contributor.authorBlanes-Vidal, V.
dc.contributor.authorPitchford, W.
dc.date.issued2011
dc.description.abstractThere has been a growing interest in improving air quality within livestock buildings. However, the influence of housing and management factors on air exchange rates and indoor gas concentrations is not well understood. The aim of this study was to determine the effects of housing and management factors on the concentrations of carbon dioxide (COâ ) and air exchange rates in 160 representative Australian pig buildings. COâ concentrations were measured, air changes per hour (ACH) were estimated using a COâ balance method, and structural and management parameters were recorded. The mean COâ concentration measured was 858 ppm and a mean air exchange rate of 22.8 ACH was estimated. The analysis showed that COâ concentrations were affected by the type of building, season, control of the wall and ridge vents, ceiling height, size of the wall vents and height of the ridge vents. Weaner buildings had the highest COâ concentrations while deep-bedding shelters had the lowest. Winter COâ concentrations were higher in all buildings compared to summer. Buildings with automated ridge ventilation control had the lowest COâ concentrations. The wall ventilation inlet height was negatively correlated with COâ concentration. Air exchange rates were primarily affected by the type of ventilation, inlet height, stocking density, and building width and height. In conclusion, the equable Australian climate has allowed the construction of cheaper pig buildings, which provide an adequate environment for pig production, although these buildings may not always provide an optimal environment for pig production.
dc.description.statementofresponsibilityT.M. Banhazi, P. Stott, D. Rutley, V. Blanes-Vidal, W. Pitchford
dc.identifier.citationBiosystems Engineering, 2011; 110(3):272-279
dc.identifier.doi10.1016/j.biosystemseng.2011.08.007
dc.identifier.issn1537-5110
dc.identifier.issn1537-5129
dc.identifier.orcidPitchford, W. [0000-0002-5213-3978]
dc.identifier.urihttp://hdl.handle.net/2440/68393
dc.language.isoen
dc.publisherAcademic Press Ltd
dc.rightsCopyright © 2011 IAgrE. Published by Elsevier Ltd. All rights reserved.
dc.source.urihttps://doi.org/10.1016/j.biosystemseng.2011.08.007
dc.titleAir exchanges and indoor carbon dioxide concentration in Australian pig buildings: Effect of housing and management factors
dc.typeJournal article
pubs.publication-statusPublished

Files