The value of the erect abdominal radiograph for the diagnosis of mechanical bowel obstruction and paralytic ileus in adults presenting with acute abdominal pain
Files
(Published version)
Date
2018
Authors
Geng, W.Z.M.
Fuller, M.
Osborne, B.
Thoirs, K.
Editors
Advisors
Journal Title
Journal ISSN
Volume Title
Type:
Journal article
Citation
Journal of Medical Radiation Sciences, 2018; 65(4):259-266
Statement of Responsibility
Conference Name
DOI
Abstract
<h4>Introduction</h4>There is discord on the value of the erect abdominal radiograph for diagnosing acute abdominal pathologies. The erect radiograph can be uncomfortable for patients in pain and increases patient radiation dose.<h4>Aim</h4>To determine if including the erect abdominal radiograph in plain abdominal radiography (PAR) improved diagnostic accuracy for identifying mechanical bowel obstruction and/or paralytic ileus in adults presenting with acute abdominal pain.<h4>Methods</h4>PAR of 40 consecutive adults presenting with suspected bowel obstruction or paralytic ileus was retrospectively sampled and independently reviewed by two emergency department (ED) consultants and two radiology consultants for bowel obstruction and paralytic ileus across two sessions. In session 1, the assessors assessed the supine abdominal radiographs (PAR 1) and clinical details in a randomised order, and session 2, at least 6 weeks later, they assessed the supine and erect radiographs (PAR 2) and clinical details of the randomly re-ordered cases. Computed tomography was the reference standard. Pair-wise comparisons of receiver operating characteristic curves were calculated to assess for significant differences in participants' diagnostic accuracy using MedCalc 16.4.3.<h4>Results</h4>Average sensitivity, specificity and area under the receiver operating characteristic curves (AUROC) were 69.7%, 61.0% and 0.642 for PAR 1, respectively, and 80.0%, 53.4% and 0.632 for PAR 2 respectively. For AUROC there were no significant differences (P > 0.05) between PAR 1 and PAR 2. Intra-rater and inter-rater agreement improved in PAR 2.<h4>Conclusion</h4>There was no statistically significant improvement in diagnostic accuracy when including the erect radiograph in PAR for the acute abdomen.
School/Discipline
Dissertation Note
Provenance
Description
Access Status
Rights
Copyright 2018 The Authors. Journal of Medical Radiation Sciences published by John Wiley & Sons Australia, Ltd on behalf of Australian Society of Medical Imaging and Radiation Therapy and New Zealand Institute of Medical Radiation Technology. This is an open access article under the terms of the Creative Commons Attribution License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited (https://creativecommons.org/licenses/by/4.0/)