Three-Dimensional Heads-up Display in Cataract Surgery: A Review.
dc.contributor.author | Muecke, T.P. | |
dc.contributor.author | Casson, R.J. | |
dc.date.issued | 2022 | |
dc.description.abstract | Intraocular visualization in cataract surgery is currently achieved using the ophthalmic surgical microscope (OSM). Three-dimensional (3D) heads-up display is a burgeoning intraocular visualization technique for cataract surgery, which projects the surgical view to a 3D monitor. A number of theoretical advantages of this system over the OSM have been proposed. 3D visualization is reported to provide improved depth perception and the heads-up display promotes a more ergonomic surgical position while providing an enhanced view for the entire surgical team. The modern OSMs, however, already allow for safe and efficient cataract surgery, and 3D heads-up display visualization is limited by a steep learning curve. We critically review the literature around 3D heads-up display cataract surgery and compare its safety profile to traditional visualization techniques. | |
dc.description.statementofresponsibility | Thomas P. Muecke, Robert J. Casson | |
dc.identifier.citation | Asia-Pacific Journal of Ophthalmology, 2022; 11(6):549-553 | |
dc.identifier.doi | 10.1097/apo.0000000000000562 | |
dc.identifier.issn | 2162-0989 | |
dc.identifier.issn | 2162-0989 | |
dc.identifier.orcid | Muecke, T.P. [0000-0003-1361-555X] | |
dc.identifier.orcid | Casson, R.J. [0000-0003-2822-4076] | |
dc.identifier.uri | https://hdl.handle.net/2440/145858 | |
dc.language.iso | en | |
dc.publisher | Wolters Kluwer | |
dc.rights | © 2022 Asia-Pacific Academy of Ophthalmology. Published by Wolters Kluwer Health, Inc. on behalf of the Asia-Pacific Academy of Ophthalmology. This is an open access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal. | |
dc.source.uri | https://doi.org/10.1097/apo.0000000000000562 | |
dc.subject | three-dimension; 3D; heads-up display; cataract surgery | |
dc.subject.mesh | Humans | |
dc.subject.mesh | Cataract | |
dc.subject.mesh | Cataract Extraction | |
dc.subject.mesh | Ophthalmology | |
dc.title | Three-Dimensional Heads-up Display in Cataract Surgery: A Review. | |
dc.type | Journal article | |
pubs.publication-status | Published |