dc.description.abstractThis study analyses three-dimensional (3D) effects during steady-state tests in short cores, primarily used to determine relative permeability (Kr) and capillary pressure (Pc). Here we concentrate on steady-state transition tests (SSTTs), which allows simultaneous determination of Kr and Pc from the steady-state data and the transition data measured between the steady states. Comparison between three- and one-dimensional (1D) modelling in short cores shows a significant difference in measured water-cut and pressure-drop data. This difference has been observed for cores with different inlet distributor geometries, aspect ratios, and anisotropy. Despite the influence of 3D flow effects on measurement data, the agreement between Kr and Pc as obtained from the 3D and 1D models is close. This phenomenon of conservative inverse-solution results has been demonstrated for different inlet distributor geometries. The Spiral distributor exhibits lower 3D flow effects and more accurate determination of relative permeability and capillary pressure from SSTT tests.
dc.description.statementofresponsibilityShuyan Yang, Nassim Hemmati, Thomas Russell, Abbas Zeinijahromi, Sara Borazjani, Aron Behr, Luis Genolet, Pavel Bedrikovetsky
dc.identifier.citationJournal of Petroleum Science and Engineering, 2022; 208(Part C):109533-1-109533-21
dc.identifier.doi10.1016/j.petrol.2021.109533
dc.identifier.issn0920-4105
dc.identifier.issn1873-4715
dc.identifier.orcidYang, S. [0000-0003-4760-2597]
dc.identifier.orcidHemmati, N. [0000-0002-6892-7203]
dc.identifier.orcidRussell, T. [0000-0001-5702-7851]
dc.identifier.orcidZeinijahromi, A. [0000-0002-3088-6952]
dc.identifier.orcidBorazjani, S. [0000-0003-3701-8143]
dc.identifier.orcidBedrikovetsky, P. [0000-0002-4786-8275] [0000-0002-7100-3765] [0000-0003-2909-6731]
dc.identifier.urihttps://hdl.handle.net/2440/146384
dc.language.isoen
dc.publisherElsevier BV
dc.rights© 2021 Elsevier B.V. All rights reserved.
dc.source.urihttps://doi.org/10.1016/j.petrol.2021.109533
dc.subjectSteady state test; Capillary pressure; Relative permeability; 3D effects; Core simulation; Laboratory coreflood
dc.title3D effects in two-phase steady-state tests
dc.typeJournal article
pubs.publication-statusPublished

Files

Collections